A cooling-water joint and a hot-acid joint are not in the same league. The definition of a critical joint under EN 1591-4, categories A/B/C, and the basics of flange management. In most operations, all flange joints are assembled in the same way – using the same procedure, by the same people, with the
In most plants, all flange joints are assembled the same way – using the same procedure, by the same people, with the same documentation. But a joint on a cooling water line and one on a hot acid line are in different leagues. The first can tolerate improvisation. The second cannot. Identifying critical joints is the first step in flange management.
EN 1591-4 defines it clearly: a joint whose failure would endanger personnel, equipment or the environment. But criticality is determined not only by the medium – it is determined by the consequences of failure:
It sounds bureaucratic. In fact, the opposite is true: 80 % of joints fall into Category C, and nothing changes for them. Attention and budget go to the 20 % that can stop production or injure someone.
Joint categorization, gasket design, torque calculations, qualified assembly, reports and guarantees – this is the scope of our Flange Management department, built on 35 years of experience. We offer plant operators the complete package: comprehensive flange joint leak-tightness solutions, torque calculations, fitter training in accordance with EN 1591-4.
Start simply: select ten joints that have cost you the most money or caused you the most headaches in recent years, and review them with us.
Discuss your critical joints →
Under EN 1591-4, it is a joint whose failure would endanger personnel, equipment or the environment. In practice, this also includes joints where a leak would have a major operational impact.
A systematic approach to joint leak-tightness: categorization, gasket design, torque calculations, qualified assembly with reports, and failure assessment.
EN 1591-4 defines qualification requirements for critical applications; customers and internal procedures are increasingly requiring them.
With an inventory and categorization. For joints with the most serious potential consequences of failure, introduce calculated torque values, qualified assembly and reporting.
© Pokorny industries s.r.o. 2026 - all rights reserved