A flanged joint is a system, not a component. How to select a gasket based on the medium and PN/DN, follow the correct installation procedure, and identify the cause of recurring leaks.
A flanged joint is a system: flanges, bolts, gasket and installation procedure. A leak is almost always a system failure, not a component failure. That’s why replacing the gasket with a “better” one so often doesn’t help.
Joint design balances points 1 and 2. Point 3 is managed during operation.
By fluid – chemical resistance is a decisive selection criterion. Aggressive fluids: PTFE (POWERflon). Steam and high temperatures: graphite (POWERgraf). General service: compressed fibre (POWERgasket). Check compatibility with the specific chemical in the chemical resistance database.
By temperature and pressure – compressed fibre up to 150 °C, PTFE −268 to 260 °C, graphite −200 to 450 °C, mica up to 900 °C. Cut flat gaskets up to 40 bar; above that, use spiral-wound, camprofile or metal gaskets.
By flange condition – camprofile or expanded graphite gaskets can accommodate damaged surfaces. Better still: repair the surfaces (flange resurfacing).
By DN/PN – with large nominal diameters and low pressure ratings, the bolts often cannot generate the required gasket stress. Solution: Improving the leak tightness of DN PN flange joints.
The specified torque is calculated for the specific joint – gasket, bolts, lubricant and fluid. That’s exactly what we do with our bolt tightening torque calculation service; you can find a table in the article Bolt Tightening Torques.
We take a systematic approach to problem joints: comprehensive leak-tightness solutions for flange joints – analysis, calculation, installation and a guarantee.
Expanded graphite – withstands 450 °C and steam cycles. For less demanding conditions, use a high-quality compressed fibre sheet.
The cause usually isn’t the gasket: insufficient or uneven preload, damaged surfaces, joint relaxation or an unsuitable design for the DN/PN.
Use a cross pattern, tightening in 3–4 steps to the calculated torque, with lubricated threads and a defined coefficient of friction.
Yes – flange resurfacing is carried out by machining the surface in place.