Relaxation of a Bolted Joint: The First 24 Hours After Assembly

Relaxation of a Bolted Joint: The First 24 Hours After Assembly

Even when a joint is assembled with perfect precision, the clamping force begins to decrease as soon as it is tightened. This phenomenon is known as relaxation. The most significant drop, often 10–20 % of the preload, occurs within the first 15 to 30 minutes after tightening, and the process continues for another 24 hours.

Causes of relaxation

  1. Micro-deformation (settling) – microscopic irregularities in the threads and bearing surfaces are flattened.
  2. Gasket creep – the sealing material shifts under pressure and accounts for the largest share of the preload loss.
  3. Change in the coefficient of friction – lubricant is squeezed out from the thread crests.

Checking the joint after assembly

In professional practice, this problem is addressed by using so-called multi-stage tightening and checking the joint after a certain period of time. For some flange joints, it is recommended to make a final inspection pass (“check pass”) with a torque wrench set to 100 % of the specified torque at least 4 hours after assembly, to compensate for the initial settling.

Are you ready to put your seal selection worries behind you? Contact us

and get valuable advice and information on industrial seals

Logo Pokorny Industries

Pokorny Industries Partnership in quality