Due to gasket creep, preload may decrease by 20–40% during the first 24 hours of operation at elevated temperatures.
Retorquing should only be performed at operating temperature (usually during warm-up to 100–150 °C) and WITH NO PRESSURE in the pipeline, or, for safety reasons, at the minimum process overpressure.
Retorquing must not be performed on elastomeric or expanded graphite gaskets after prolonged service at high temperatures, when the material has already become brittle. There is a risk of the material breaking down and causing an immediate failure.
Retorquing after reaching operating temperature must always be assessed in relation to the specific application.