Tightness curves vs. PT diagrams: what your gasket supplier will (and won’t) show you

A PT diagram tells you that the seal will “hold up.” A leakage curve tells you how well it seals under your operating conditions. Why ask your supplier for measured curves?

Tightness curves vs. PT diagrams: what your gasket supplier will (and won’t) show you

Most suppliers’ catalogs include a PT diagram: a pressure–temperature graph showing the area of application. It looks scientific, but it answers just one question: “Will it hold up?” It says nothing about how well the joint will seal. For that, you need measured leakage curves. And those are what distinguish a manufacturer who knows its material from a catalog distributor.

What a PT diagram leaves out

  1. Tightness is not a yes-or-no matter. Every joint leaks to some extent—the question is how much. Leakage is measured, and standards define tightness classes based on the permissible leakage rate (designations according to EN 13555 – L1,0 / L0,1 / L0,01…).
  2. Tightness depends on gasket stress. The same gasket seals very differently at 20 and 50 MPa of compressive stress. A PT diagram does not include this dimension.
  3. The material degrades in operation – relaxation, settling, cycling. The curves show how it behaves, not just its limit.

What a leakage curve is

A laboratory-measured relationship between leakage and gasket stress for a given medium, temperature, and material thickness.

The curve tells you exactly what a real joint needs:

Without curves, torque calculation is just bolt mechanics. With curves, it becomes a tightness calculation – and that is what matters to the operator. That is why we base our torque calculations on measured parameters.

Why many suppliers do not provide curves

Testing is expensive, requires an accredited laboratory – and the results come with accountability. A material that looks universal in a PT diagram may require unrealistically high compression to meet a stricter tightness class.

A simple way to test a supplier: ask for leakage curves for the specific material. A reputable manufacturer will provide them – just as they will provide a TGA purity analysis for graphite. The answer “the PT diagram is all you need” speaks for itself.

When curves matter most

You do not need to worry about curves for cooling water. But for a joint that could halt production or endanger personnel, they are the difference between engineering and guesswork.

Discuss gasket selection based on measured parameters →


FAQ

What is a gasket PT diagram?

A graph showing the pressure and temperature range in which the material can withstand the mechanical loads. It says nothing about the amount of leakage.

What is a leakage curve?

A measured relationship between leakage and gasket stress. It lets you calculate the compression – and therefore the torque – required to achieve the specified tightness class.

What are tightness classes?

Categories of permissible leakage defined by a standard. A stricter class generally requires higher gasket stress.

Why do manufacturers not publish curves?

Testing is expensive, and the results come with accountability. Measured curves are a sign of a manufacturer who knows their materials.

Are you ready to put your seal selection worries behind you? Contact us

and get valuable advice and information on industrial seals