• Online sales

VAT 127 L – compact vertical multistage pump

Flow rate up to 14 m³/h (233 l/min), head 7–131 m, motor 1.5–4 kW. Noryl diffusers, AISI 304 shaft. Jockey pump for fire protection systems. Single-phase 230 V and three-phase 400 V.

Variants

No results...

Product description

VAT 127 L is a compact vertical multistage pump with 1 1/2" suction and discharge threaded connections. A flow rate of up to 14 m³/h (233 l/min) and ten configurations based on the number of stages (4 to 13) provide a head range from 7 m to 131 m.

With motors rated at 1.5–4 kW, the VAT 127 L is ideal as a jockey pump in fire protection systems (SHZ), maintaining pipeline pressure while consuming minimal energy. It is also suitable for smaller booster sets in apartment buildings and commercial premises. Available in single-phase 230 V (versions up to 5.5 CV) and three-phase 400/690 V configurations.

Suction and discharge casing made of GG-25 cast iron, hydraulic chamber made of AISI 304. Impellers and diffusers made of Noryl (injection-moulded GFN-2 technopolymer with brass inserts) – wear-resistant and quiet in operation. Shaft and diffuser casing made of AISI 304 stainless steel. Ceramic/graphite mechanical seal with easy access. Counter-flanges included.

The inlet and outlet ports are on the same side – a version with ports on opposite sides is available on request.

Main technical specifications

ParameterValue
Model rangeVAT (SACI pumps)
Configurations (versions)127 L-4, L-5, L-6, L-7, L-8, L-9, L-10, L-11, L-12, L-13
Suction / discharge connection1 1/2" / 1 1/2" thread
Flow range Q0–14 m³/h (0–233 l/min)
Head range H7–131 m (depending on the number of stages)
Motor power P21.5–4 kW (2–5.5 HP)
Power supply230 V 1-phase (up to 5.5 CV) · 400/690 V 3-phase
Speed2 850 rpm
Pumped liquid temperatureup to 45 °C
Max. ambient temperature45 °C
Motor protection ratingIP-55
Insulation classF (155 °C)
Operating modeS1 (continuous duty)
Impeller and diffuser materialNoryl GFN-2 (with brass inserts)
Shaft and casing materialAISI 304 stainless steel
Suction/discharge casing materialGG-25 cast iron
Mechanical sealceramic/graphite
Counter-flangesincluded

Q-H operating curve

VersionQ=0345678910111214
L-44140,54038363430272318147
L-551504947454238342923179
L-66159,558565450464035282113
L-7717068666359544740332514
L-8818078767268625547383017
L-9918988858276706152433319
L-101019997959185786959493822
L-1111110910710510194867766554325
L-12121119117115110103948573614828
L-131311291271251201121029380675330

(Q in m³/h, H in metres of water column)

The standard maximum operating head and maximum operating flow rate are highlighted on the chart with a solid line.

Applications

  • Jockey pump in fire protection systems – maintains pressure in fire-fighting pipework with minimal power consumption.
  • Small booster stations – apartment buildings, guesthouses, smaller commercial properties.
  • Auxiliary pump – boosts pressure in closed circuits.
  • Irrigation systems – small gardens and greenhouses.
  • Boiler make-up – low-capacity feed circuits (up to 45 °C).

Key benefits

  • 10 configurations – the widest selection of stages in the VAT range, from L-4 (1.5 kW) to L-13 (4 kW).
  • Compact dimensions – smaller than the XV-F, it fits into confined plant rooms.
  • Counter-flanges included – ready for immediate installation.
  • Noryl components – wear-resistant and quiet-running.
  • 230 V availability – single-phase versions available where no three-phase connection is available.
  • Ports on the same side – easy to install in a pipe run.

Optional accessories

  • O-rings: POWERseal EPDM
  • Frequency converter 1.5–4 kW, depending on the version
  • Version with ports on opposite sides – available on request

What is a jockey pump, and why is the VAT 127 L suitable?

A jockey pump maintains pressure in fire-fighting pipework when the main pump is not running. It needs to be reliable, compact and energy-efficient. The VAT 127 L, with 1.5–4 kW motors and a head of up to 131 m, is well suited to this role – it maintains system pressure with minimal power consumption.

What is the difference between the VAT 127 L and the V-NOX 300?

Both have a similar performance range, but differ in design. The V-NOX 300 has a stainless steel casing (AISI 304) and is designed for extremely quiet operation. The VAT 127 L has a cast-iron suction casing with Noryl components and is primarily intended for use as a jockey pump or in small booster stations. The VAT 127 L offers 10 configurations (vs. 8 for the V-NOX 300) and a higher flow rate (14 vs. 11 m³/h).

What is the warranty?

VAT pumps come with a 24-month warranty.

Features

Feature Value Unit
DNA = input / suction
40 DN
DNM = output / displacement
40 DN
Flow rate Q
0 to 14 m³/h
Displacement range H
7 to 131 m
Temperature of the pumped medium
0 to 45 °C

Don't see the right gasket in our offer?

We can create the perfect seal for your needs, including non-standard sizes.

Contact us

You might find it useful

VAT 163 L – compact vertical multistage pump
  • Online sales

VAT 163 L – compact vertical multistage pump

Flow rate up to 26 m³/h (433 l/min), head 12–154 m, motor 3–9,3 kW. Noryl diffusers, AISI 304 shaft. 2" connection. Three-phase 230/400 V and 400/690 V.

View
VAT 205 – vertical multistage pump
  • Online sales

VAT 205 – vertical multistage pump

Flow rate up to 45 m³/h (750 l/min), head 23–158 m, motor 7.5–18.5 kW. Noryl diffusers, AISI 304 shaft. 2 1/2" connection. Three-phase 400/690 V.

View

Are you ready to put your seal selection worries behind you? Contact us

and get valuable advice and information on industrial seals

Logo Pokorny Industries

Pokorny Industries Partnership in quality

All prices excluding VAT

© Pokorny industries s.r.o. 2026 - all rights reserved